Using software travel limits – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 63

Advertising
background image

Phoenix 9.76.0 Installation and Setup Manual 806410

63

2 – Machine Setup

Using software travel limits

A software travel limit (also called a

software overtravel) is a position on the axis that can be reached before the system

contacts a hardware limit switch or hard stop. The drawing below shows measurements from an example system with a
gantry that has 154 inches (3912 mm) of travel on the Transverse axis between the overtravel switches.

The gantry travel distance of 154 inches (3912 mm) also equals the Table Size X dimension on the Machine Setups
screen (Setups > Password > Machine Setups).

Gantry

1

2

3

4

5

Add a hard
stop to the
left of 2.
Need to
allow
enough
space to
stop
without
breaking
your hard
stop

1

Gantry distance between hardware overtravel switches
154 inches (3192 mm)

2

X- overtravel switch at 0.

3

X+ overtravel switch at154 inches (3912 mm)

4

Software minimum travel limit at 3 inches (76 mm) to stop
motion before contact with the hardware overtravel
switch.

5

Software maximum travel limit at 151 inches (3835 mm)
to stop motion before contact with the hardware
overtravel switch.

Advertising