Oxyfuel outputs – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 267

Advertising
background image

Phoenix 9.76.0 Installation and Setup Manual 806410

267

15 – Oxyfuel Application

Raise Torch / Raise All Torches: This input can be used as a toggle switch that turns on the Torch Up output. The

Torch Up output signals the oxyfuel torch lifter to raise the torch.

Torch Down Sense: When this input turns on, the CNC turns off the Torch Down output. This input is used with a lower

limit switch or proximity switch on the oxyfuel torch lifter, but not as a safety switch. The Torch Down Sense
input does not cause a fault on the CNC.

Torch Up Sense: When this input turns on, the CNC turns off the Torch Up output. This input is used as an upper limit

switch proximity switch on the oxyfuel torch lifter, but not as a safety switch. The Torch Down Sense input
does not cause a fault on the CNC.

Oxyfuel outputs

The oxyfuel outputs are controlled by timers on the Oxyfuel Process screen. The screen below shows an example of
output assignments for an oxyfuel cutting system with two torches.

Note: In a cutting system that combines plasma and oxyfuel, when assigning I/O for oxyfuel cutting stations, use
numbered I/O 9 – 20.

Advertising