Analog input diagnostics, Inputs, Analog inputs – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 202

Advertising
background image

202

Phoenix 9.76.0 Installation and Setup Manual 806410

8 – Diagnostics

Analog Input Diagnostics

Note: The appearance of the View screen depends on the type of Analog Input Card that is installed.

Inputs

The Analog Input Card is required to operate the optional joystick and speed pots is equipped with six low voltage inputs
that are optically isolated and can operate at 24 – 120 VAC/DC. The first four inputs are used for the optional joystick
feature. Inputs 5 and 6 are used to support THC1 and THC2 Nozzle Contact Sense respectively. These inputs are
normally-open.

Analog Inputs

The Analog Input values shown in the upper right hand of the screen are the voltages coming into the analog card. Analog
Inputs 1 and 2 are used for THC1 and THC2. Analog inputs 3 and 4 are used for optional external speed pots.

Advertising