Serial communication interface, Rs-422c connections to hpr cnc interface, Powermax plasma supply – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 164

Advertising
background image

164

Phoenix 9.76.0 Installation and Setup Manual 806410

7 – Plasma Setup

Serial communication interface

RS-422C connections to HPR CNC interface

Powermax plasma supply

Hypertherm CNCs support a serial connection to the Powermax65

®

, Powermax85

®

, and Powermax105

®

. From the CNC

you can set cut mode (normal cutting or continuous pilot arc), current, and gas pressure. A diagnostic screen helps you
monitor the status of the Powermax system.

Setting up a Powermax system in Phoenix requires the following steps:

Select the Powermax65 or Powermax85 in the Station Configuration screen.

Assign the Powermax to a serial port.

Assign I/O for the Powermax.

Selecting the Powermax in the Station Configuration screen

1. Choose Setups > Password and enter your password to open the Station Configuration screen.

2. For Station 1 (or the station you want to set up for the Powermax), choose your Powermax model from the drop-down

list.

Control (male)

Supply (male)

Signal name

DB-9 pin

Signal name

DB-37 pin

TxD-

2

RxD-

1

RxD-

3

TxD-

2

TxD+

4

RxD+ 20

RxD+

7

TxD+ 21

Advertising