Phoenix 9.76.0 Installation and Setup Manual 806410

241

Section 12

Serial Ports

Hypertherm CNCs support two serial ports that can be set for either RS-422 or RS-232 communications. Both serial
ports are set to RS-422 at the factory. To change either serial port to RS-232, you must change a jumper setting on the
serial isolation board that is inside the CNC. The jumper positions are clearly marked on the board.

The serial ports in the CNC are specifically designed to operate with a standard nine-pin serial port connector. The
following table provides specifications for these ports:

CAUTION

Set the port for the chosen type of serial operation (RS-422 or RS-232) before connecting
compatible devices.

Channel Type

Optically isolated RS-232C or RS-422

Information Code

ASCII

Baud Rate

User-selectable up to 115.2K baud

Number of Start Bits

1

Number or Stop Bits

1

Word Length

User-selectable 7 or 8 bits

Parity

User-selectable none, even or odd

Data Synchronization XON (Control-Q) / XOFF (Ctrl/S)

Time Out

User-selectable in one-second increments

Transmit Delay

User-selectable in 0.01-second increments

Rear Panel Connector IBM-PC/AT compatible 9-pin D-type female