Phoenix 9.76.0 Installation and Setup Manual 806410

59

2 – Machine Setup

Dual Tilt Rotator Installed: Choose this option when the cutting system has a second ACXYZ bevel head. Choosing

this option also enables a second transverse axis that can be used for a second straight torch, or for a chuck
to turn round pipe or rectangular tube stock.

Auto Home at Power Up: Determines whether the contour bevel head (CBH) and tilt or rotate axes automatically go

into the homing routine when the CNC powers up.

Follower Initially: Determines whether the CBH and rotate features are always enabled after power up or are enabled

through the part program.

Dual Tilting Rotator: Dual Tilting Rotator describes an ABXYZ bevel head which has two tilt axes (A and B). Choose

this option when your cutting system has this type of bevel head installed. The Tilt Rotator Installed option
must be selected to make Dual Tilting Rotator option available.

Dual Transverse: Enables the Transverse 2 axis for use with a second cutting station or as an axis for a chuck for

holding pipe or tube stock.

Table Size: Enter between the X overtravel switches and the Y overtravel switches. The X and Y dimensions represent

the cutting area of the table and limit the workpiece size dimensions set in the Cutting screen.

Key Press Logging: Records key press and other related information in a daily log file. Service technicians use this log

to review events before a fault. When logging is enabled, the log file is saved to the hard drive so it can be
retrieved by transfer to a USB memory stick. Usually this parameter is set to NO.

ArcGlide THCs Installed: Defines the number of ArcGlide THC axes assigned to the CNC.

Use Hypernet: Sets up the CNC to communicate with the ArcGlide over Hypernet.

Sensor THCs Installed: Defines the total number of Sensor THC axes assigned to the CNC.

THC Installed On Axis / Analog: Defines the torch height control axis. Select the THC, which axis it is installed on,

and the analog input to use for arc voltage feedback.

For more information on the setup and use of the Sensor THC, refer to the other
sections in this chapter, as well as

Torch Height Controls in the Phoenix Operator’s

Manual.

Ignore Torch Collision During IHS: Allows the system to ignore input about a torch collision during the initial height

sense cycle. This may be helpful for some THC mechanics.

Command THCs Installed: Enables the Command THC serial link. For more information on this feature, refer to

Configuring Ports on page 87. Shown in Type P mode only.

Auto Torch Spacing: Select Yes to enable the automatic torch spacing feature. This feature uses embedded part

program codes and dedicated outputs to control individual torch stations to set spacing and clamping of
direct and mirrored cutting. For more information, refer to the

Phoenix V9 Series Programmer’s Reference.