Phoenix link configuration – Hypertherm V9 Series Phoenix Rev.11 User Manual

Page 90

Advertising
background image

90

Phoenix 9.76.0 Installation and Setup Manual 806410

2 – Machine Setup

Phoenix Link Configuration

Port Designation: Specifies which serial port is configured for link use with the following remote communication

settings. Choose Link, Messaging, or a serial-capable cutting system such as Powermax, HPR,
MAXPRO200, or HyPrecision™ waterjet.

Time Out: Specifies the amount of time the CNC waits before it displays a communications error if it is not able to

establish a link with a remote device.

Baud Rate: Specifies the baud rate for the remote communication link. The available baud rates are shown. The CNC

also incorporates a unique compression utility that allows the effective baud rate to be doubled. For example,
for links configured to run at 9600 baud, the effective rate is 19.2K baud.

For serial messaging communication speeds from 1200 baud to 115200 baud are
available. See

Serial Messaging in the Phoenix V9 Series Programmer’s Reference

(806420) for more information.

ESSI Program Termination: This parameter allows the operator to tell the CNC which ESSI code (0, 63, 64 99,

/ or =) is used as machine stop.

Using Phoenix Link: Select Yes if you are using the Phoenix Communication link program that is supplied on the CNC.

The CNC automatically enters the appropriate ASCII codes to the communication link dialog parameters
listed previously.