Troubleshooting steps

1. Review the settings in the Station Configuration screen. Does each station have:

a. A station must have a process assigned that matches the cut mode.

b. The processes assigned to the station must be valid.

c. A physical tool with processes that match the station settings must be installed.

2. Review station I/O assignments.

a. Verify that the station I/O is assigned properly.

b. Each station should be: Auto Select # / Manual Select # / Station Enable LED #.

c. If one station has station I/O, all stations need station I/O.

3. Verify the settings.

a. Verify the Tools Installed on the Special Setups screen.

b. Verify that all processes (for Tools Installed) are assigned on the Station Configuration screen.

c. Verify that station I/O is assigned properly on the I/O screen.

d. Verify that Station Select Override and Process Select Override are enabled on the Cutting screen if you are

using M36 Tx codes to select a process from the part program.

4. Monitor the station I/O and processes (Watch Window).

a. Monitor the Station Enable LED outputs.

b. Monitor the Process Enable outputs.

c. Monitor Process Data for each available process (preferably in one Watch Window).