Nortel Networks Circuit Card User Manual

Page 106

Advertising
background image

Page 106 of 906

Option settings

553-3001-211 Standard 3.00 August 2005

BIMP
(Notes 1, 4)

600

ohms

3COM1

3COM2

600

ohms

3COM1

3COM2

3COM2

Gain treatment
(Note 5)

No

Yes

Table 14
OPS analog line card configuration (Part 3 of 3)

Application

On-premise station (ONS)

Off-premise station (OPS)

Class of Service
(CLS) (Note 1)

ONP

OPX

Note 1: Configured in the Analog (500/2500-type) Telephone Administration program (LD 10).

Note 2: The maximum signaling range supported by the OPS analog line card is 2300 ohms.

Note 3: Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to
loop resistance ranges for 26 AWG wire.

Note 4: Default software impedance settings are:

ONP CLS

OPX CLS

TIMP:

600 ohms

600 ohms

BIMP:

600 ohms

3COM2

Note: Gain treatment, such as a voice frequency repeater (VFR) is required to limit the actual
OPS loop loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss
greater than 15 dB (equivalent to a maximum signaling range of 2300 ohms on 26 AWG wire) is
not recommended.

Note: Jumper strap settings JX.0 and JX.1 apply to all eight units; “X” indicates the unit
number, 0–7. “Off” indicates that a jumper strap is not installed across both pins on a jumper
block. Store unused straps on the OPS analog line card by installing them on a single jumper
pin as shown below:

553-5924

Jumper block

Jumper strap

Jumper pin