Switch SW4 – Carrier Shield Grounding

This switch enables for the selective grounding of the Tx / Rx pairs of the
carrier cable. Closing the switch (down position) applies Frame Ground
(FGND) to the coaxial carrier cable shield, creating a 75 ohms unbalanced
configuration. This applies only to the NTBK05CA cable.

Note: The usual method is to ground the outer conductor of the receive
coaxial signal.

Power requirements

The NTAK79 obtains its power from the backplane, drawing maximums of
2 A on +5 V, 50 mA on +12 V and 50 mA on –12 V.

Environment

The NTAK79 meets all applicable Nortel Network’s operating specifications.

Functional description

The NTAK79 card provides the following features and functions:

recovery of the 2.048 kbps data by the CEPT receiver, at signal levels
which have been attenuated by up 10 dB

control of CEPT line density using HDB3 which provides 64 kbps clear
channel

performance monitoring of the receive carrier by means of Bipolar
Violations (BPV), Slips, CRC-4 (CRC), and Frame Bit Errors (FBER)

Table 243
Switch SW4

Switch

Down (On)

Up (Off)

SW 4-1

Rx – FGND

Rx – OPEN

SW 4-2

Tx – FGND

Tx – OPEN