NTCK16 Generic Central Office Trunk cards
553-3001-211 Standard 3.00 August 2005
Equivalencies
The following equivalencies do apply:
•
XFCOT COT SHL is equivalent with XUT COT TRC
•
XFCOT COT LOL is equivalent with XUT COT NTC.
The entries TRC and NTC will no longer be allowed for the Generic XFCOT.
Trunk to Trunk connection
When any disconnect supervision is configured (CLS = BAT, BTS) the Loop
Start Trunk of the Generic XFCOT will be marked as having disconnect
supervision and will therefore follow the same rules as a Ground Start Trunk.
There is no configuration involved for this operation.
Call disconnect
When any disconnect supervision is configured (CLS = BAT, BTS) the Loop
Start Trunk will be released when the disconnect signal is received. This will
apply also in call states such as ringing, camp-on, DISA, and Meridian Mail.