Page 518 of 906

NT7D16 Data Access card

553-3001-211 Standard 3.00 August 2005

required. The defaults are bracketed, and may be issued by Carriage Return
(<CR>).

LD 11 – Configure Data Access card. (Part 1 of 3)

Prompt

Response

Description

REQ:

NEW CHG MOV
COPY

Add, change, move or copy the unit

TYPE:

R232
R422

RS-232-C unit
RS-422 unit

TN

l s c u

DAC data TN. The loop (LL) must be a superloop.

RNPG

<CR>

Ringing number pickup group (default to zero)

CLS

DTA
ADD

Class of Service allowed for the DAC.

Data Allowed
Digit Display Allowed

TOV

(0) - 3

Timeout value, where:

0 = no timeout
1 = 15 minutes
2 = 30 minutes
3 = 60 minutes

OPE

(NO) YES

Operation parameter change

PAR

(SPAC) ODD EVEN
MARK

SPAC = space parity
ODD = odd parity
EVEN = even parity
MARK = mark parity

DTR

(OFF) ON

DTR settings, where:

ON = forced DTR
OFF = dynamic DTR

This prompt appears only if TYPE = R232