Nortel Networks Circuit Card User Manual
Page 399

NT6D80 MSDL card
Page 399 of 906
Circuit Card
Description and Installation
Table 148 lists the synchronous interface specifications and the means of
configuring the interface parameters.
Asynchronous transmission uses an internal clock to generate the appropriate
baud rate for serial controllers.
Table 149 lists asynchronous interface specifications and the means of
configuring interface parameters.
Table 148
Synchronous interface specifications
Parameter
Specification
Configured
Data bits
In packets-Transparent
N/A
Data rate
1.2, 2.4, 4.8, 9.6, 19.2, 38.4,
48, 56, and 64 kbps
Software
Transmission
Full Duplex
N/A
Clock
Internal/External
Software
Interface
RS-232
Software
RS-422
Switches
Mode
DTE or DCE
Switches
Table 149
Asynchronous interface specifications (Part 1 of 2)
Parameter
Specification
Configured
Data bit, parity
7 bits even, odd or no
parity, or 8 bits no parity
Software
Data rate
0.3, 0.6, (1.2), 2.4, 4.8,
9.6, 19.2, and 38.4 kbps
Software
Stop bits
1 (default), 1.5, 2
Software
Transmission
Full Duplex
N/A
Interface
RS-232
Software