Carrier grounding – Nortel Networks Circuit Card User Manual

Page 755

Advertising
background image

NTAK79 2.0 Mb PRI card

Page 755 of 906

Circuit Card

Description and Installation

Impedance matching

The line interface provides for the use of either 75 ohms coaxial or 120 ohms
twisted pair cable. The impedance is selected by a switch, as shown in
Table 245.

Note: The ON position for all the switches is towards the bottom of the
card. This is indicated by a white dot printed on the board next to the
bottom left corner of each individual switch.

Carrier grounding

The NTAK79 card provides the capability of selectively grounding the shield
of the Tx and/or Rx pairs of the carrier. Closing (down) the on-board switch
applies FGND to the appropriate carrier cable shield. The switch settings are
shown in Table 246.

Receiver functions

The receiver extracts data and clock from an AMI (Alternate Mark Inversion)
coded signal and outputs clock and synchronized data. The receiver is
sensitive to signals over the entire range of cable lengths and requires no
equalization. The clock and data recovery meets or exceeds the jitter
specifications of the CCITT recommendation G.823, and the jitter attenuation

Table 245
Impedance matching switch selection

Cable

On

Off

75 ohms

S2

S1

120 ohms

S1

S2

Table 246
Carrier shield grounding switch settings

Switch

Carrier Pair

On

Off

S4-1

Rx shield

Open

GND

S4-2

Tx shield

Open

GND