Xmfe sender and receiver specifications – Nortel Networks Circuit Card User Manual
Page 375

NT5K21 XMFC/MFE card
Page 375 of 906
Circuit Card
Description and Installation
XMFE sender and receiver specifications
provide the operating requirements
for the XMFC/MFE card when it is configured as an XMFE card. These
requirements conform to French Socotel specifications ST/PAA/CLC/CER/
692.
Tone Interrupt no release:
< 8 msec. Receiver on, while tone missing
Longest Input tone ignored:
< 8 msec. Combination of valid frequencies
Noise rejection:
S/N > 18 dB No degradation, in band white noise
S/N > 13 dB Out-of-band disturbances for CCITT
Table 145
XMFE sender specifications
Forward frequencies in OG mode:
700, 900, 1100, 1300, 1500 Hz
Forward frequencies in IC mode:
1900 Hz
Frequency tolerance:
+/- 0.25% from nominal
Power level at each frequency:
Selectable: 1 of 16 levels
Level tolerance:
+/- 1.0 dB
Harmonic Distortion and Intermodulation:
35 dB below level of 1 signaling frequency
Time interval between start of 2 tones:
125 usec.
Time interval between stop of 2 tones:
125 usec.
Table 144
XMFC receiver specifications (Part 2 of 2)