QPC513 Enhanced Serial Data Interface card
Page 865 of 906
Circuit Card
Description and Installation
Software service changes
All of the other ESDI port operating parameters are defined in software and
downloaded to the assigned ESDI port. See Table 266 on
changes are made using the Configuration Record program (LD 17).
Instructions for the Configuration Record program are found in the Software
Input/Output: Administration (553-3001-311).
Some of the prompts that are commonly used when running the Configuration
Record program (LD 17) are shown in LD 17 – Serial port configuration
Table 271
ESDI card DTE/DCE mode jumper settings
Mode
Port
Jumper socket
designations
Data communication equipment (DTE)
1
UA10
UA12
Data terminal equipment (DCE)
1
UA9
UA11
Data communication equipment (DTE)
2
UA17
UA19
Data terminal equipment (DCE)
2
UA16
UA18
Table 272
ESDI card RS-232-C/high-speed interface jumper settings
Mode
Port
Jumper socket
designations
RS-232-C interface
1
UB9
UB11
High-speed interface
1
UB10
UB12
RS-232-C interface
2
UB16
UB18
High-speed interface
2
UB17
UB19