Electrical specifications, T1 channel specifications – Nortel Networks Circuit Card User Manual

Page 202

Advertising
background image

Page 202 of 906

NT5D11 and NT5D14 Lineside T1 Interface cards

553-3001-211 Standard 3.00 August 2005

Man-Machine Interface

The lineside T1 card provides an optional Man-Machine Interface (MMI) that
is primarily used for T1 link performance monitoring and problem diagnosis.
The MMI provides alarm notification, T1 link performance reporting and
fault isolation testing. The interface is accessed through connections from the
I/O panel to a terminal or modem.

The MMI is an optional feature since all T1 configuration settings are
performed through dip switch settings or preconfigured factory default
settings.

Electrical specifications

T1 channel specifications

Table 77 provides specifications for the 24 T1channels. Each characteristic is
configured by dip switches.

Table 77
Lineside T1 card – line interface unit electrical characteristics

Characteristics

Description

Framing

ESF or D4

Coding

AMI or B8ZS

Signaling

Loop or ground start A/B robbed-bit

Distance to Customer Premise
Equipment (CPE) or Channel
Service Unit

0-199.6 meters (0–655 feet)

Advertising