If ?<CR> is typed, the MMI will list the above commands along with an
explanation of their usage A screen similar to the following will appear. The
help screen can also appear by typing H<CR>, or HELP<CR>.
Each of these commands can be executed by typing the first letter of the
command or by typing the entire command. Command sets are entered by
typing the first letter of the first command, a space, and the first letter of the
second command or by typing the entire command. Table 88 shows all the
possible command sets, listed in alphabetical order. These commands are
described by subject later in this section.
ALARM
USAGE: Alarm [Enable | Disable]
CLEAR
USAGE: Clear [Alarm] | [Error counter] [Log]
DISPLAY
USAGE: Display [Alarm | Status | Perform |
History] [Pause]
HELP
USAGE: Help | ?
SET
USAGE: Set [Time | Date | Alarm | Clearing |
Name | Memory]
TEST
USAGE: Test [Carrier All]
QUIT
USAGE: Quit
Notation Used:
CAPS - Required Letters [ ] -
Optional
| - Either/
Or
Table 88
MMI commands and command sets (Part 1 of 3)
Command
Description
A D
Alarm Disable
Disables all alarms.
A E
Alarm Enable
Enables all alarms.
C A
Clear Alarm
Clears all alarms, terminates line processing, and resets the T1 bit error rate and
frame slip counters.
C A L
Clear Alarm Log
Clears the alarm log.