Physical description – Nortel Networks Circuit Card User Manual

Page 567

Advertising
background image

NT8D14 Universal Trunk card

Page 567 of 906

Circuit Card

Description and Installation

Table 184 lists the signaling and trunk types supported by the NT8D14
Universal Trunk card.

Physical description

The trunk and common multiplexing circuitry is mounted on a 31.75 cm by
25.40 cm (12.5 in. by 10 in.) printed circuit board.

The NT8D14 Universal Trunk card connects to the backplane through a
160-pin connector shroud. The backplane is cabled to the I/O panel, which is
cabled to the Main Distribution Frame (MDF) by 25-pair cables. External
equipment, such as recorded announcement machines, paging equipment,
and Central Office facilities, connect to the card at the MDF.

See the Communication Server 1000S: Installation and Configuration
(553-3031-210) for termination and cross-connect information.

Table 184
Trunk and signaling matrix

Signaling type

Trunk types

CO/FX/

WATS

DID

Tie

RAN

Paging

CAMA

Loop start

Yes

No

(see note)

No

N/A

N/A

Yes

Ground start

Yes

No

No

N/A

N/A

No

Loop DR

No

Yes

Yes

N/A

N/A

No

Loop OAID

No

No

Yes

N/A

N/A

No

Continuous operation
mode

No

No

No

Yes

N/A

No

Start modes
(pulse and level)

No

No

No

Yes

N/A

No

Note: For incoming and outgoing service, DID trunks must be programmed as loop dial
repeating.