NT8D41BA Quad Serial Data Interface Paddle Board

Page 691 of 906

Circuit Card

Description and Installation

Software service changes

Once the NT8D841BA QSDI paddle board has been installed in the system,
the system software needs to be configured to recognize it, using the
Configuration Record program LD 17. Instructions for running this program
are found in Software Input/Output: Administration (553-3001-311).

Some of the prompts that are commonly used when running the Configuration
Record program LD 17 are shown in LD 17 – Prompts to configure the
NT8D841Ba paddle board. These parameters
must be set for each port if both
ports are being used.

LD 17 – Prompts to configure the NT8D841Ba paddle board.

Prompt

Response

Description

REQ:

CHG

Change configuration

TYPE:

ADAN

Configuration type

ADAN

NEW TTY x

NEW PRT x

Define a new system terminal (printer) port as device x, where
x = 0 to 15.

CTYPE

SDI4

Quad port card

DES

XQSDI

Quad density QSDI paddle board.

USER

xxx

Enter the user of port x. The values that can be entered
depend on the software being used. See the Software Input/
Output: Administration
(553-3001-311) for details.

XSM

(NO) YES

Port is used for the system monitor.