Software service changes, Software service changes” on – Nortel Networks Circuit Card User Manual
Page 691

NT8D41BA Quad Serial Data Interface Paddle Board
Page 691 of 906
Circuit Card
Description and Installation
Software service changes
Once the NT8D841BA QSDI paddle board has been installed in the system,
the system software needs to be configured to recognize it, using the
Configuration Record program LD 17. Instructions for running this program
are found in Software Input/Output: Administration (553-3001-311).
Some of the prompts that are commonly used when running the Configuration
Record program LD 17 are shown in LD 17 – Prompts to configure the
NT8D841Ba paddle board. These parameters must be set for each port if both
ports are being used.
LD 17 – Prompts to configure the NT8D841Ba paddle board.
Prompt
Response
Description
REQ:
CHG
Change configuration
TYPE:
ADAN
Configuration type
ADAN
NEW TTY x
NEW PRT x
Define a new system terminal (printer) port as device x, where
x = 0 to 15.
CTYPE
SDI4
Quad port card
DES
XQSDI
Quad density QSDI paddle board.
USER
xxx
Enter the user of port x. The values that can be entered
depend on the software being used. See the Software Input/
Output: Administration (553-3001-311) for details.
XSM
(NO) YES
Port is used for the system monitor.