Cable installation, Procedure 17 cabling the msdl card to the pri card, D in table 155 on – Nortel Networks Circuit Card User Manual

Page 410

Advertising
background image

Page 410 of 906

NT6D80 MSDL card

553-3001-211 Standard 3.00 August 2005

Note: The choices of cable to use with an MSDL card depend on what
type of modem is connected. For example, the NTND27 cable is used
when the modem has a DB25 connection. If the modem is v.35, a
customized or external vendor cable is required.

Cable installation

When the MSDL card is installed, connect the cables to the equipment
required for the selected operation.

PRI trunk connections

D-channel operations require connections between the MSDL and a PRI
trunk card. Refer to Meridian Link ISDN/AP General Guide (553-2901-100)
for a complete discussion of PRI and D-channels.

Procedure 17
Cabling the MSDL card to the PRI card

The following steps explain the procedure for cable connection:

1

Identify the MSDL and the PRI cards to be linked.

2

Select the appropriate length cable for the distance between the MSDL
and the PRI card.

3

Plug the 26-pin SCSI II male connector end of a cable into the appropriate
MSDL port.

4

Route the cable through cable troughs, if necessary, to the appropriate
PRI card.

Table 155
Cable types

Function

Cable type

Cable length

DCH

NTND26AA
NTND26AB
NTND26AC

NTND26AD

6 feet

18 feet
35 feet
50 feet

AML, ISL, SDI

NTND27AB

6 feet