Jumper strap settings – Nortel Networks Circuit Card User Manual
Page 618

Page 618 of 906
NT8D14 Universal Trunk card
553-3001-211 Standard 3.00 August 2005
Jumper strap settings
For most applications, the jumper strap settings remain set to the standard
configuration as shipped from the factory. See Table 190 on
.
The jumper strap settings must be changed, as shown in Table 191 on
, for the following:
•
For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)
Table 192
Trunk types – termination impedance and balance network (NT8D14BA, NT8D14BB)
Trunk types
Terminating
impedance
(Note 1)
Balance network for loop lengths (Note 2)
0–915 m
(0–3000 ft)
915–1524 m
(3000–5000 ft)
> 1524 m
(> 5000 ft)
CO/FX/WATS
600 or 900
ohms
600 ohms
3COM
3CM2
2-way TIE (LDR)
600 or 900
ohms
600 ohms
3COM
3CM2
2-way TIE (OAID)
600 or 900
ohms
600 ohms
3COM
3CM2
DID (loop length
< 600 ohms)
600 or 900
ohms
600 ohms
3COM
3CM2
DID (loop length
Š 600 ohms)
600 or 900
ohms
600 ohms
N/A
3CM2
RAN: continuous
operation mode
600 or 900
ohms
600 or 900 ohms
N/A
N/A
Paging
600 ohms
600 ohms
N/A
N/A
Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and
should match the nominal impedance of the connecting equipment.
Note 2: The balance network of each trunk unit is software selectable between resistive 600 or
900 ohms or 3COM and jumper selectable between 3COM and 3CM2. Jumper selection for
3COM/3CM2 restriction does not apply to NT8D14BB.