NT6D80 MSDL card

553-3001-211 Standard 3.00 August 2005

Previously operating MSDL cards

Problems that occur during normal operation usually result from faulty cards.
Follow these steps to evaluate the situation:

1

Use the

STAT MSDL x

command to check MSDL card status. See

“Displaying MSDL status” on

page 418

.

2

If the card has been manually disabled, try to enable it using

ENL MSDL x

. See “Enabling the MSDL” on

page 417

. If this fails,

perform self-testing as described in step 4.

3

If the card has been disabled by the system, disable it manually with

DIS MSDL x

. See “Disabling the MSDL” on

page 418

.

4

Invoke self-testing with the

SLFT MSDL x

command. See “Self-testing

the MSDL” on

page 418

. If self-tests fail, replace the card. If self-tests

pass, try to enable the card again, as in step 2. If the card does not enable,
note the message output to the TTY and follow the recommended action.