Several cabling schemes are possible for both AILC and RILC modes.
Typical capacitance for 24- and 26-gauge cables is shown in the Tables 168
and 169. RS-232 and RS-422 transmission distance is limited by the electrical
capacitance of the cable. Low-capacitance cable carries a digital signal
further than a high-capacitance cable.

Figure 98 on

page 510

shows the cabling choices available. It includes

cabling with the RS-232-C cable, associated patch panel, the RJ-11, and the
octopus cable. Each scheme can be tailored to suit individual needs, and
specific alternatives are shown in later figures.

Table 168
RS-232-C maximum line capacitance 2,500 µF

Gauge

Capacitance per foot (µF)

Max distance

24

24

104

26

15

166

Table 169
RS-422 maximum line capacitance 60,000 µF

Gauge

Capacitance per foot (µF)

Max distance

24

24

2500

26

15

4000