Option settings

553-3001-211 Standard 3.00 August 2005

A set of three switches provides selection of dB values. Use SW5, SW6, and
SW7 for Trunk 0; use SW11, SW12, and SW13 for Trunk 1 (see Table 17).

A set of four DIP switches provides selection among three values for receiver
impedance. Use SW8 for Trunk 0; use SW14 for Trunk 1 (see Table 18).

Table 17
Trunk interface line build out switch settings

Switch Setting

Description

SW5/SW11

SW6/SW12

SW7/SW13

0 dB

off

off

off

7.5 dB

on

on

off

15 dB

on

off

on

Table 18
Trunk interface impedance switch settings

Description

SW8/SW14 Switch Settings

75

off

off

on

off

100

on

off

off

on

120

off

off

off

on