Option settings

553-3001-211 Standard 3.00 August 2005

NT6D42 Ringing Generator DC

Tables 22 through 27 list option settings for the NT6D42 Ringing Generator.

Table 22
NT6D42 recommended options for North American and British Telecom

Application

Ringing
frequency

Ringing
voltage

Jumper locations

Ringing output

North America

20 Hz

86 V ac

P5
High voltage
message waiting

Low impedance

British Telecom

25 Hz

80 V ac

P4
No high voltage
message waiting

Low impedance

Table 23
NT6D42 jumper locations P4 and P5

High voltage message waiting

Pin location

Disable

Jumper in P4

Enable

Jumper in P5

Note: One jumper must be installed.

Table 24
NT6D42 jumper location J7

Ringing output

Jumper location J7

Low impedance (normal)

Connect pins 1 and 2

High impedance (Australia)

Connect pins 2 and 3