Table 124 on – Nortel Networks Circuit Card User Manual

Page 344

Advertising
background image

Page 344 of 906

NT5D97 Dual-port DTI2/PRI2 card

553-3001-211 Standard 3.00 August 2005

Note: Do not change this setup.

Receiver impedance

A per-trunk set of four DIP switches (S8/S14 provides selection between 75
or 120 ohm values. Refer to Table 125.

Ring ground switches for NT5D97AA/AB

A set of four Dip switches (S2) selects which Ring lines are connected to
ground. Refer to Table 126.

Table 124
Trunk interface line build out switch settings

Switch setting

Description

S5/S11

S6/S12

S7/S13

0dB

OFF

OFF

OFF

Table 125
Trunk interface impedance switch settings

Description

S8/S14 switch setting

75 ohm

OFF

OFF

ON

OFF

120 ohm

OFF

OFF

OFF

ON

Table 126
Ring ground switch settings (Part 1 of 2)

Switch

Description

S2 switch settingS

1

Trunk 0 Transit

OFF-Ring line is not grounded
ON- Ring line is grounded

2

Trunk 0 Receive

OFF-Ring line is not grounded
ON- Ring line is grounded