Nortel Networks Circuit Card User Manual
Page 628

Page 628 of 906
NT8D15 E&M Trunk card
553-3001-211 Standard 3.00 August 2005
Note: In Cabinet systems equipped with Meridian Mail, the Universal
Trunk line card cannot be installed in slot 10 of the main cabinet.
The NT8D15 E&M trunk card supports the following types of trunks:
•
2-wire E&M Type I signaling trunks
•
two-wire dial repeating trunks
•
two or four wire tie trunks
•
4-wire E&M trunks:
— Type I or Type II signaling
— duplex (DX) signaling
•
paging (PAG) trunks
Type I signaling uses two signaling wires plus ground. Type II and DX
signaling uses two pairs of signaling wires. Most electronic switching
systems use Type II signaling.
Table 196 lists the signaling and trunk types supported by the NT8D15 E&M
trunk card.
Table 196
Trunk and signaling matrix
Signaling
Trunk types
RLM/RLR
TIE
PAG
CSA/CAA/CAM
2-wire E&M
Yes
Yes
Yes
Yes
4-wire E&M
Yes
Yes
No
Yes
Legend:
RLM
Release Link Main
RLR
Release Link Remote
CSA
Common Control Switching Arrangement
CAA
Common Control Switching Arrangement with Automatic Number Identification (ANI)
CAM
Centralized Automatic Message Accounting (CAMA) trunk