Installation, Maintenance – Nortel Networks Circuit Card User Manual

Page 76

Advertising
background image

Page 76 of 906

Overview

553-3001-211 Standard 3.00 August 2005

Electromagnetic interference

The CS 1000S, CS 1000M, and Meridian 1 systems meet the requirements of
FCC Part 15 and CSA C108.8 electromagnetic interference (EMI) standards
as a class “A” computing device. To accomplish this, the SDI cables must exit
the module through EMI filters on the I/O panel.

Reliability

The Mean Time Between Failure (MTBF) for all SDI cards is 55 years at
40°C and 29 years at 55°C.

Installation

To use a serial data interface card in a CS 1000S, CS 1000M, or Meridian 1
system, first install the card in the system, and then configure the system
software to recognize it. These steps are discussed in the following sections.

Instructions for cabling the serial data interface cards to the various system
consoles and peripherals are found in Communication Server 1000M and
Meridian 1: Large System Installation and Configuration
(553-3021-210).

Configuring the system software

Once an SDI card has been installed in the system, the system software needs
to be configured to recognize it. This is done using the Configuration Record
program LD 17. Instructions for the Configuration Record program are found
in Software Input/Output: Administration (553-3001-311).

Maintenance

The following maintenance programs are used to maintain individual SDI
asynchronous ports. The program used depends on the application of the port.

LD 37 Input/Output Diagnostics – Used for system terminal, printer,
background terminal ports, and system monitor status.

LD 42 Call Detail Recording (CDR) Diagnostic – For checking CDR
links and CDR system terminals.