Qpc525, qpc526, qpc527, qpc777 co trunk card – Nortel Networks Circuit Card User Manual

Page 145

Advertising
background image

Option settings

Page 145 of 906

Circuit Card

Description and Installation

QPC525, QPC526, QPC527, QPC777 CO Trunk card

Note 1: There is no ground start signalling for QPC777 CO trunk cards.
Always select loop start signalling for QPC777 CO trunk cards.

Note 2: On QPC777 CO trunk cards, the pads are in for short line
lengths and the pads are out for long line lengths.

Application

Switches at E29/E9/A29/A11 Units 0/1/2/3

1

2

3

4

5

6

7

8

Zero ohm outpulsing

on

off

off

Standard outpulsing

off

on

off

Ground start

on

on

off

Loop start

off

off

off

Loop start, automatic guard detection

off

on

off

PPM daughterboard not installed

on

off

PPM daughterboard installed

off

off

Battery on M operation

off

on

off

Ground on M operation

on

off

off

Second pair M&MM

off

off

off

Advertising