Power requirements, Foreign and surge voltage protections – Nortel Networks Circuit Card User Manual

Page 557

Advertising
background image

NT8D09 Analog Message Waiting Line card

Page 557 of 906

Circuit Card

Description and Installation

Power requirements

Table 180 provides the power requirements for the NT8D09 Analog Message
Waiting Line card.

Foreign and surge voltage protections

In-circuit protection against power line crosses or lightning is not provided on
the NT8D09 Analog Message Waiting line card.

Table 180
Power requirements

Voltage
(+/-)

Tolerance

Idle
current

Active
current

Max

+ 12.0 V dc

0.36 V dc

48 mA

0 mA

48 mA

+ 8.0 V dc

0.40 V dc

150 mA

8 mA

280 mA

–48.0 V dc

2.00 V dc

48 mA

40 mA

688 mA

–48.0 V dc

5.00 V dc

0 mA

10 mA
(Note 1)

320 mA

86.0 V ac

5.00 V ac

0 mA

10 mA
(Note 2)

160 mA

–150.0 V dc

3.00 V dc

0 mA

2 mA

32 mA

Note 1: Each active ringing relay requires 10 mA of battery voltage.

Note 2: Reflects the current for ringing a single station set (or DN
telephone). There may be as many as five ringers on each line.