Environmental specifications, Operation – Nortel Networks Circuit Card User Manual

Page 168

Advertising
background image

Page 168 of 906

NT1R20 Off-Premise Station Analog Line card

553-3001-211 Standard 3.00 August 2005

Environmental specifications

Table 67 shows the environmental specifications of the OPS analog line
card.

Operation

The applications, features, and signaling arrangements for each unit on the
NT1R20 OPS analog line card are assigned through LD 10 and/or jumper
strap settings on the card.

The operation of each unit is configured in software and implemented in the
card through software download messages. When the NT1R20 OPS analog
line card unit is idle, it provides a ground on the tip lead and –48 V dc on the
ring lead. The on-hook telephone presents a high impedance toward the line
interface unit on the card.

OPS Loop Range

Maximum Number of
Ringers (REN)

0 – 10 ohms

3

> 10 – 900 ohms

2

> 900 – 2300 ohms

1

Table 67
OPS analog line card – environmental specifications

Parameter

Specifications

Operating temperature

0° to +60° C (+32 to +140° F),
ambient

Operating humidity

5 to 95% RH (non-condensing)

Storage temperature

–40° to +70° C (–40° to +158° F)

Table 66
OPS analog line card – ringer limitations (Part 2 of 2)

Advertising