Figure 8
Battery reversal answer and disconnect supervision sequence

System

High-

resistance

loop

Line card unit idle

(2-way voice

connection)

Remarks

Ground on tip/
battery on ring

Signal/direction

State

Ground on tip/
battery on ring

High-

resistance

loop

Ground on tip/

battery on ring

Far-end station

on hook

Near-end station

on hook

If near-end station hangs up first, a high-resistance loop is
presented to the system.

If far-end station hangs up first, the system detects
disconnect signalling from the far end, removes timeslot
assignments, and restores normal ground/battery polarity
to the near-end station.

No battery current drawn.

Near-end station goes off hook. Battery current is drawn
causing detection of off-hook state. The system
determines unit terminal number (TN) and assigns
message timeslots.

Low-resistance loop

Dial tone is applied to the near-end station from the
system.

Call request

Dial tone

Addressing signals

Outpulsing

Near-end station dials number (loop pulsing or DTMF
tones).

Dial tone removed

The system detects start of dialing and removes dial tone.

Ringback (or busy)

The system decodes addressing, routes call, and supplies
ringback tone to near-end station if far-end station is on
hook. (Busy tone supplied if far-end station is busy.)

When call is answered (either absolute or assumed
answer, as programmed), ringback tone is removed, call
is cut through to far-end station, and battery is reversed
to near-end station for duration of call.

The system detects drop in loop current, removes timeslot
assignments, sends disconnect signal to far-end station,
and restores normal ground/battery polarity to the near-
end station. Line card unit is then ready for the next call.

High-

resistance

loop

Near-end station detects battery reversal and goes on
hook. Line card unit is then ready for the next call.

High-

resistance

loop

Line card unit idle

Line card unit idle

Low-

resistance

loop

Line
card

Near-end

station

Far-end

station

Battery on tip/
ground on ring

Low-

resistance

loop

Battery on tip/
ground on ring

Ground on tip/

battery on ring

Note 1:

Battery reversal signalling is a supervisory feature that is only used when the near-end station
originates the call.