NT8D41AA Serial Data Interface Paddle Board
Page 673 of 906
Circuit Card
Description and Installation
Option switch settings
Address
Address select switch SW4 and logic on the card always address the two
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 15 and 16. The
settings for this switch are shown in Table 212.
Baud rate
Switches SW2 and SW3 determine the baud rate for each individual port. The
settings for these switches are shown in Table 213 on
.
Table 212
SDI paddle board address switch settings
Address
Switch SW4
Port 1
Port 2
1
2
3
4
0
1
off
on
on
on
2
3
off
on
on
off
4
5
off
on
off
on
6
7
off
on
off
off
8
9
off
off
on
on
10
11
off
off
on
off
12
13
off
off
off
on
14
15
off
off
off
off