Power requirements, Environmental specifications, Foreign and surge voltage protection – Nortel Networks Circuit Card User Manual

Page 654

Advertising
background image

Page 654 of 906

NT8D15 E&M Trunk card

553-3001-211 Standard 3.00 August 2005

Power requirements

Table 204 lists the power requirements for the E&M trunk card.

Environmental specifications

Table 205 provides the environmental specifications for the E&M trunk card.

Foreign and surge voltage protection

The E&M trunk card meets CS03 over-voltage (power cross) specifications
and FCC Part 68 requirements.

Table 204
Power requirements

Voltage

Tolerance

Max current

+15.0 V dc

±5%

200 mA

–15.0 V dc

±5%

200 mA

+8.5 V dc

±2%

200 mA

–48.0 V dc

±5 %

415 mA

Table 205
Environmental specifications

Parameter

Specifications

Operating temperature

0 to +60 degrees C
(32 to +140 degrees F), ambient

Operating humidity

5 to 95% RH (non-condensing)

Storage temperature

–40 to +70 degrees C
(–40 to +158 degrees F)

Advertising