Electrical specifications, Power requirements, Environmental specifications – Nortel Networks Circuit Card User Manual

Page 796

Advertising
background image

Page 796 of 906

NTCK16 Generic Central Office Trunk cards

553-3001-211 Standard 3.00 August 2005

Electrical specifications

Power requirements

Table 256 shows the power requirements for the NTCK16AX and
NTCK16BX generic Central Office trunk cards.

Note 1: Analog circuitry is powered with +/-12 V generated from
+/-15 V. The maximum current imbalance between the +/-15 V rails is
100 ma per circuit pack.

Note 2: 8.5V is regulated to give 5 V.

Environmental specifications

Table 257 lists the environmental specifications of the NTCK16AX and
NTCK16BX generic Central Office trunk cards.

Table 256
NTCK16 circuit card power requirements

Voltage

Idle Current

Active current

+15.0 V dc

(See 1)

170 ma

330 ma

-15.0 V dc

(See 1)

170 ma

249 ma

+8.5 V dc

(See 2)

101 ma

100 ma

+5.0 V dc

160 ma

322 ma

Table 257
NTCK16 circuit card environmental specifications (Part 1 of 2)

Parameter

Specifications

Operating temperature

10 to 45 degrees C

Operating humidity

20 to 80% RH (non-condensing)