NT8D15 E&M Trunk card

553-3001-211 Standard 3.00 August 2005

Trunk circuit features

Trunk unit functions

The functions provided by each unit on the E&M trunk card include 2-wire
signaling, 4-wire signaling, and paging operation as follows:

2-wire, E&M Type I signaling (see Figure 144 on

page 635

) with:

— near-end seizure and outpulsing with M lead

— ground detection with E lead

— voice transmission through tip and ring for transmit and receive

4-wire, E&M Type I and II signaling (see Figure 145 on

page 636

),

2-way dial repeating with:

— echo suppression for Type I signaling

— switchable 7 dB and 16 dB pads for carrier interface

— voice transmission and reception through two separate paths

— Type I signaling through E&M leads

— Type II signaling with near-end seizure by SB/M leads and far-end

detection by E/SG lead

4-wire, DX signaling (see Figure 146 on

page 637

)

paging trunk operation (see Figure 147 on

page 638

) with support access

by low-resistance path at the PG/A1 leads

Note: Paging end-to-end signaling is not supported.