Carrier grounding – Nortel Networks Circuit Card User Manual

Page 781

Advertising
background image

NTBK50 2.0 Mb PRI card

Page 781 of 906

Circuit Card

Description and Installation

Impedance matching (Switch SW2)

The line interface provides for the use of either 75 ohms coaxial or 120 ohms
twisted pair cable. The impedance is selected by SW2, as shown in Table 251.

Note: The ON position for all the switches is toward the bottom of the
card. This is indicated by a white dot printed on the board next to the
bottom left corner of each individual switch.

Carrier grounding

NTBK50 enables the shield of the Tx and/or Rx pairs of the carrier to be
selectively grounded. Closing (down position) the on-board switch applies
FGND to the appropriate carrier cable shield. The switch settings are shown
in Table 252.

Table 251
Impedance matching switch settings

Cable Type

SW 2-1

75 ohms

Down (On)

120 ohms

Up (Off)

Table 252
Carrier Shield grounding switch settings

Switch

Down (On)

Up (Off)

SW 4 – 1

Rx – FGND

Rx – OPEN

SW 4 – 2

Tx – FGND

Tx – OPEN