Nortel Networks Circuit Card User Manual
Page 75

Overview
Page 75 of 906
Circuit Card
Description and Installation
Power consumption
The SDI cards obtain their power directly from the module backplane. Power
consumption for each of the cards is shown in Table 10.
Environmental
The SDI cards operate without degradation under the conditions listed in
Table 11.
Electrostatic discharge
The SDI cards meet the requirements of the IEC 801-2, clause 8.0 procedure.
They can withstand a direct discharge of ±5 to ±20 kV without being
damaged.
Table 10
Power consumption
Voltage
Maximum power consumption
NT8D41BA
QPC513
QPC841
+5 VDC ±5%
1.0 Amp
3.0 Amp
1.5 Amp
+12 VDC ±5%
100 mA
50 mA
100 mA
–12 VDC ±5%
100 mA
50 mA
100 mA
Table 11
Environmental specifications
Specification
Operation
Storage
Ambient temperature
0° to 50°C;
(32° to 122°F)
–55° to +70°C;
(–58° to 158°F)
Relative humidity
(non-condensing)
5% to 95%
0% to 95%
Altitude
3500m;
(11000 ft)
15000m;
(50000 ft)