Page 75 of 906

Circuit Card

Description and Installation

Power consumption

The SDI cards obtain their power directly from the module backplane. Power
consumption for each of the cards is shown in Table 10.

Environmental

The SDI cards operate without degradation under the conditions listed in
Table 11.

Electrostatic discharge

The SDI cards meet the requirements of the IEC 801-2, clause 8.0 procedure.
They can withstand a direct discharge of ±5 to ±20 kV without being
damaged.

Table 10
Power consumption

Voltage

Maximum power consumption

NT8D41BA

QPC513

QPC841

+5 VDC ±5%

1.0 Amp

3.0 Amp

1.5 Amp

+12 VDC ±5%

100 mA

50 mA

100 mA

–12 VDC ±5%

100 mA

50 mA

100 mA

Table 11
Environmental specifications

Specification

Operation

Storage

Ambient temperature

0° to 50°C;

(32° to 122°F)

–55° to +70°C;

(–58° to 158°F)

Relative humidity

(non-condensing)

5% to 95%

0% to 95%

Altitude

3500m;

(11000 ft)

15000m;

(50000 ft)