Xmfr receiver specifications – Nortel Networks Circuit Card User Manual

Page 697

Advertising
background image

NTAG26 XMFR card

Page 697 of 906

Circuit Card

Description and Installation

XMFR receiver specifications

Table 220 provides the operating requirements for the NTAG26 circuit card.

Table 220
XMFR receiver specifications (Part 1 of 3)

Coding:

Mu-Law

Input sensitivity:

must accept: 0 to -25 dBmO
must reject: -35 to dBmO

Frequency sensitivity:

must accept: f +/- (1.5% + 5Hz)

Amplitude Twist:

must accept: difference of 6dB between frequencies

Signal Duration:

must accept: > 30 ms
must reject: < 10 ms

KP Signal Duration:

must accept: > 55 ms
may accept: > 30 ms
must reject: < 10 ms

Signal Interruption Bridge:

must ignore: < 10 ms

Time Shift between 2 frequencies:

(Envelop for start/stop)

must accept: < 4 ms

Coincidence between 2 frequencies:

must reject: < 10 ms

Intersignal Pause:

must accept: > 25 ms

Maximum Dialling Speed:

must accept: 10 signals per second