Each of these commands can be executed by entering the first letter of the
command or by entering the entire command. Commands with more than one
word are entered by entering the first letter of the first word, a space, and the
first letter of the second word or by entering the entire command. Table 105
shows all possible MMI commands in alphabetical order. These commands
are also described later in this section.

Table 105
MMI commands and command sets (Part 1 of 2)

Command

Description

A D

Alarm Disable. Disables all alarms.

A E

Alarm Enable. Enables all alarms.

C A

Clear Alarm. Clears all alarms, terminates time processing, and resets
the E1 bit error rate and frame slip counters.

C A L

Clear Alarm Log. Clears alarm log.

C E

Clear Error. Clears the E1 error counter.

D A(P)

Display Alarms. Displays the alarm log, which is a list of the 100 most
recent alarms with time and date stamps. (Momentarily stop the
scrolling display by typing P. Continue scrolling by typing any other key.)

D C(P)

Display Configuration. Displays the configuration settings for the
LEI(s), single- or multiple-card system. Display includes each card’s
serial number, MMI firmware version, date and time, alarm
disable/enable setting, self-clearing disable/enable setting, values
entered through the Set Configuration command, and dip switch
settings.(Momentarily stop the scrolling display by typing P. Continue
scrolling by typing any other key.)

D H(P)

Display History. Displays performance counters for the past 24 hours.
(Momentarily stop the scrolling display by typing P. Continue scrolling by
typing any other key.)

D P

Display Performance. Displays performance counters for the current
hour.