Pad switching

The NTCK16AX and NTCK16BX generic Central Office trunk cards
support the North American loss plan. Software configuration allows the
selection of 4 dB loss pads on a per unit basis.

Note: The tolerance for the above nominal values is +0.3 dB, -0.7 dB.

Connector pin assignments

Cross connections

Figure 167 on

page 798

, Figure 168 on

page 799

, and Figure 169 on

page 800

provide cross connect information for the NTCK16AX and

NTCK16BX generic Central Office trunk cards.

Configuration

The trunk type for each unit on the card is selected by software service change
entries at the system terminal.

Storage temperature

–20 to +60 degrees C

Storage humidity

5 to 95% Relative Humidity

Table 258
NTCK16 pad switching

Loss

Analog-to-Digital

Digital-to-Analog

PAD out

0 dB

–3 dB

PAD in

+4 dB

+1 dB

Table 257
NTCK16 circuit card environmental specifications (Part 2 of 2)

Parameter

Specifications

Advertising