NT5D33 and NT5D34 Lineside E1 Interface cards

553-3001-211 Standard 3.00 August 2005

Table 108 shows which test to run for the associated equipment.

Test 1, local loopback, loops the E1 link signaling toward itself at the
backplane connector. Test data is generated and received on all timeslots. If
this test fails, it indicates that the LEI is defective. Figure 59 illustrates how
the signaling is looped back toward itself.

Figure 59
MMI Local loopback test

Test 2, external loopback, applies an external loopback to the E1 link. Test
data is generated and received by the LEI on all timeslots. If test 1 passes but
test 2 fails, it indicates that the E1 link is defective between the LEI and the
external loopback location. If test 1 was not run and test 2 fails, the E1 link or
the LEI could be defective. To isolate the failure to the E1 link, tests 1 and 2
must be run in tandem. Figure 60 on

page 309

demonstrates how an external

loopback is applied to the E1 link.

Table 108
MMI Tests

Test number

Equipment Tested

Test Description

1

LEI

Local loopback

2

E1 link, LEI, and E1
network

External loopback

3

CPE device and E1
network

Network loopback

E-1 link

Line side

E-1

interface

card

Customer

premise

equipment

(CPE)

Common

Equipment

System

External

network

E-1 link

553-1160