Page 98 of 906

Acceptance tests

553-3001-211 Standard 3.00 August 2005

For other than an NT8D17 Conference/TDS card, enter:
ENLL loop

4

Test the TDS loop:
TDS loop

If the system response is other than OK, see the Software Input/Output:
Administration
(553-3001-311) to analyze the messages.

5

End the session in LD 34:
****

6

Using a maintenance telephone, log into the system.

See “Communicating with the Meridian 1” in the Software Input/Output:
Administration
(553-3001-311) for details on accessing the system using
a maintenance telephone.

7

From the maintenance telephone, enter:
LD#34##

To test outpulsers and channels for the TDS loop, see Table 13 on

page 98

for a sample of the input commands used with the maintenance

telephone. See the Software Input/Output: Administration
(553-3001-311) for all tones that can be tested.

8

Exit LD 34 from the maintenance telephone:
****

End of Procedure

Table 13
TDS tone tests

Input command

Dial pad
equivalent

Description

BSY#loop##

279#loop##

Provides busy tone from TDS loop specified.

C##

2##

Removes any active tone.

DIA#loop##

342#loop##

Provides dial tone from TDS loop specified.

OVF#loop##

683#loop##

Provides overflow tone from TDS loop specified.

RBK#loop##

725#loop##

Provides ringback tone from TDS loop specified.

Advertising