Nortel Networks Circuit Card User Manual

Page 616

Advertising
background image

Page 616 of 906

NT8D14 Universal Trunk card

553-3001-211 Standard 3.00 August 2005

Table 190
Jumper strap settings – factory standard (NT8D14BA, NT8D14BB)

Trunk types

Loop length

Jumper strap settings (Note 1)

J1.X

J2.X

J3.X

J4.X

(Note 2)

CO/FX/WATS

0–1524 m (5000 ft.)

Off

Off

1–2

1–2

2-way TIE (LDR)

2-way TIE (OAID)

DID

0–600 ohms

Off

Off

1–2

1–2

RAN: continuous
operation mode

Not applicable: RAN
and paging trunks
should not leave the
building.

Off

Off

1–2

1–2

Paging

Note 1: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; “X” indicates
the unit number, 0–7. “Off” indicates that no jumper strap is installed on a jumper block. Store
unused straps on the universal trunk card by installing them on a single jumper pin as shown
below.

Note 2: For the NT8D14BB card, J4.X is not provided on the card. The J4.X jumper setting
specified in Table 190 does not apply.

Jumper pin

Jumper block

Jumper strap

553-6317