Circuit Card

Description and Installation

Architecture

Clock operation

There are two types of clock operation - tracking mode and free-run mode.

Tracking mode

In tracking mode, the DDP2 loop supplies an external clock reference to a
clock controller. Two DDP2 loops can operate in tracking mode, with one
defined as the primary reference source for clock synchronization, the other
defined as the secondary reference source. The secondary reference acts as a
back-up to the primary reference.

As shown in Figure 77, a system with dual CPUs can have two clock
controllers (CC-0 and CC-1). One clock controller acts as a back-up to the
other. The clock controllers should be completely locked to the reference
clock.

Free run (non-tracking) mode

The clock synchronization of the can operate in free-run mode if:

no loop is defined as the primary or secondary clock reference,

the primary and secondary references are disabled, or

the primary and secondary references are in local (near end) alarm