Figure 137 on – Nortel Networks Circuit Card User Manual

Page 602

Advertising
background image

Page 602 of 906

NT8D14 Universal Trunk card

553-3001-211 Standard 3.00 August 2005

Figure 137
Two-way, loop OAID, TIE trunk call connection sequence – outgoing call to far-end PBX

A

State

Remarks

Signal/direction

Near end

System

B

Far end

PBX

High-

resistance

loop

Low-resistance loop

High-resistance loop

High-resistance loop

Ground
on tip/
battery
on ring

Ground on tip/
battery on ring

Ground on tip/
battery on ring

Battery on tip/
ground on ring

Terminal A goes off hook and dials access
code. Near end reverses battery and ground
on tip and ring, alerting far end.

Far end detects battery/ground reversal and
answers call by placing a low resistance
between tip and ring.

Near end monitors loop current during 2-way
voice connection.

If far end disconnects first, it opens the loop.

Near end detects drop in loop current and
reverses battery and ground on tip and ring.

If near end disconnects first, it reverses
battery and ground on tip and ring.

Far end detects battery/ground reversal and
opens loop.

553-AAA1148

Idle

Idle

Idle

Trunk seizure

B goes on hook

A goes on hook

2-way voice

connection

Advertising