Appendix A: LAPB Data Link Control protocol

553-3001-211 Standard 3.00 August 2005

LAPB subset of the HDLC protocol and transmitted serially to the line at a
rate determined by the downloaded parameters.

The QPC513 card receives data serially from the line, packaged in LAPB
information frames. After determining that a block is error free the data is
supplied to the Circuit Switch Equipment as a block.

Frame structure

All transmissions are in frames and each frame conforms to the format shown
in Table 280 on

page 903

. In particular, frame elements for applications using

a port on the QPC513 follow these LAPB conventions:

Zero information field is permitted.

Inter-frame time fill is accomplished by transmitting contiguous flags.
This is compatible with AT&T Technical Requirement BX.25 and
ADCCP standards.

Extensions for the address field or the control field are not permitted.
This requirement imposes constraints to satellite operations.

Individual station addresses are assigned in service change for balanced
configuration. The default ESDI address is 10000000. The far-end
default address is 11000000.

The LAPB basic control field (modules 8) format is implemented.

Frame check sequence is implemented in accordance with LAPB
procedures.