NT5D11 and NT5D14 Lineside T1 Interface cards

553-3001-211 Standard 3.00 August 2005

The “Disable Self-Clearing” option causes the system to continue the alarm
condition until the Clear Alarm (C A) command set is entered. Line
processing and the yellow alarm indication to the CPE is terminated as soon
as the alarm condition clears, even if “Disable Self-Clearing” is set.

Display Configuration

The Display Configuration (D C) command set displays the various
configuration settings established for the lineside T1 card. Entering the
Display Configuration (D C) command set causes a screen similar to the
following to appear:

LTI S/N 1103 Software Version 1.01 3/03/95 1:50

Alarms Enabled: YES

Self Clearing Enabled: YES

Alarm Level 1 threshold value: E-7 Threshold duration

(in seconds): 10

Alarm Level 2 threshold value: E-5 Threshold duration

(in seconds): 1

Frame slips alarm level threshold: 5 Threshold duration

(in hours): 2

Current dip switch S1 settings (S1..S8) On Off Off On Off

Off Off On

Current dip switch S2 settings (S1..S8) On Off On Off Off

Off On Off

Alarm operation and reporting

The MMI monitors the T1 link according to the parameters established
through the Set Alarm command set for the following conditions:

Excessive bit error rate

Frame slip errors

Out of frame condition

Loss of signal condition

Blue alarm (AIS) condition