Overview

553-3001-211 Standard 3.00 August 2005

configure the card according to instructions issued by the system

report back to the system information such as card identification (type,
vintage, and serial number), firmware version, and programmed
configuration status)

Intelligent Peripheral Equipment

IPE line cards all have a similar architecture. Figure 2 on

page 34

shows a

typical IPE line card architecture. The various line cards differ only in the
number and types of line interface units.

The switch communicates with IPE modules over two separate interfaces.
Voice and signaling data are sent and received over DS-30X loops, and
maintenance data is sent over a separate asynchronous communication link
called the card LAN link.

Signaling data is information directly related to the operation of the telephone
line. Some examples of signaling commands include:

off-hook/on-hook

Table 3
IPE module architecture

Parameter

IPE

Card Dimensions

31.75 x 25.4 x 2.2 cm.

(12.5 x10.0 x 0.875 in.)

Network Interface

DS-30X Loops

Communication Interface

card LAN Link

Microcontroller

8031 / 8051 Family

Peripheral

Interface card

NT8D01 Controller card

Network Interface card

NT8D04 Superloop Network card

Modules

NT8D37 IPE module